BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//theinstitutenc.org - ECPv6.14.2//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://theinstitutenc.org
X-WR-CALDESC:Events for theinstitutenc.org
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20260308T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20261101T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20260108
DTEND;VALUE=DATE:20260109
DTSTAMP:20260429T210109
CREATED:20260106T182038Z
LAST-MODIFIED:20260106T182038Z
UID:10000431-1767830400-1767916799@theinstitutenc.org
SUMMARY:Crooked Run Creek/Farm Pump Station and Force Main Replacement
DESCRIPTION:Jimmy R. Lynch & Sons\, Inc. An Equal Employment Opportunity Contractor\, NC General Contractors # 7706 Will Consider All Quotes Regardless of Race\, Color\, Religion\, Sex\, or National Origin and is Soliciting Bids for M/WBE Participation.\nWe would appreciate a quotation from your firm for any and all work and/or materials on the following project:\n \nProject Name: Crooked Run Creek/Farm Pump Station Upgrade and Force Main Replacement\n \nBid Date:  Thursday\, January 8th\, 2026 at 2:00 PM\n \nPlease provide your proposal by:  Wednesday\, January 7th\, 2026 at 5:00 PM\n \nThis project consists of upgrades to the pump station including new pumps\, electrical equipment\, piping\, gallery\, flow meter\, new mechanical bar screen\, the installation of approximately 120 LF of 24” PVC Gravity Sewer\, 15\,372 LF of 18” PVC Force main and 6\,952 LF of 20” PVC force main.\nWe are soliciting subcontract bids for the following trades. Work may include\, but not limited to: temporary bypass watering\, manhole protective coating\, chain link fencing\, plug valves\, parshall flumes\, cast in place concrete\, demolition\, clearing and grubbing\, erosion control\, site grading\, asphaltic concrete paving\, sanitary sewerage collection\, electrical\, submersible pumps and controls\, crushed stone paving\, washer compactor\, mechanical bar screen\, dewatering\, excavate backfill for structures\, trenching and backfill\, jack and bore\, along with any incidentals and materials necessary for construction to complete the project.\nThe work performed under this Contract shall include but may not be limited to the furnishing of all labor\, materials\, equipment and services\, whether specifically mentioned or not\, that is required to complete the Construction of the Work of the project. All requirements of the State of North Carolina and all pertinent administrative regulations shall apply to this project as if herein written out in full.\n \nPlease contact Daniel Lynch at dlynch@jrlynchandsons.com if you have any questions about the project or submitting a proposal.\n \nThe following link will provide you with the digital Plans and Specs:\n \nhttps://www.dropbox.com/scl/fo/ywgcu8qjnvtnqgnq9mmhb/AB7OOEyTwyG0ghdyvoWIRVk?rlkey=futlkdke0f2uhxi2uu1ux9sht&st=cg6q1ns9&dl=0\n \nYou may view plans & specs at the following location:  JRL Office @ 314 S. Academy St. Pilot Mtn\, NC. \n \nJRL is willing to review any responsible quote and will negotiate terms\, if appropriate.  We will notify your firm if your bid is accepted for this project.  Please contact Daniel Lynch @ number listed below\, if you have not heard from JRL by 1-15-2026 and I will inform you of the status of your bid.   If you need assistance with equipment\, obtaining bonding\, (J.R.L. will furnish bonds for all projects & will help you obtain the proper certification\, (if you are not certified.) loan capital\, lines of credit\, insurance or joint pay agreements\, please see JRL terms below or contact us and we will review your needs and direct you to available agencies for assistance. \n \nBonding:  It is Jimmy R. Lynch & Sons\, Inc. policy NOT to require M/WBE subcontractors to provide bonding to Jimmy R. Lynch & Sons\, Inc. for their portion of the work. All M/WBE subcontractors will be allowed to work under Jimmy R. Lynch & Sons\, Inc Performance & Payment Bonds to the Owner.\n \nIf you would like to obtain a bond on this project to help build your bonding capacity\, please let us know through email\, phone call or specifying on your quote and we will put you in contact with our Bonding Agent. \n \nFinancial Assistance:  Jimmy R. Lynch & Sons\, Inc. will provide Joint Check Agreements to all M/WBE subcontractors. Please request a Joint Check Agreement in writing. We will work with you and the material vendor to develop a Joint Check Agreement to satisfy all parties.\n \n Quick Payments:  It is Jimmy R. Lynch & Sons\, Inc. policy to provide Quick Payments to all M/WBE subcontractors. Jimmy R Lynch & Sons\, Inc will provide payment to all M/WBE subcontractors on a weekly basis if the work for which payment is being requested is complete and accepted by the Owner.\nJRL encourages 2nd tier M/WBE Subcontracting opportunities.  We encourage our subcontractors to utilize 2nd and 3rd tier M/WBE Subcontractors.  \nPlease Submit Quote the Day Prior to Bid Opening Phone: 336-368-4047   Fax: 336-368-4613
URL:https://theinstitutenc.org/event/crooked-run-creek-farm-pump-station-and-force-main-replacement/
CATEGORIES:Bid Opportunities
END:VEVENT
END:VCALENDAR